Woodstock M1113 Saw User Manual


 
-9-
M1113 18" Wood/Metal Bandsaw
ELECTRICAL
ELECTRICAL
DO NOT work on your electrical system
if you are unsure about electrical
codes and wiring! Seek assistance from
a qualified electrician. Ignoring this
warning can cause electrocution, fire,
or machine damage.
220V Operation
The Model M1113 operates on 220V single-phase power.
We recommend connecting this machine to a dedicated
circuit with a verified ground, using the circuit size given
below. Never replace a circuit breaker with one of higher
amperage without consulting a qualified electrician to
ensure compliance with wiring codes. This machine must
be connected to a grounded circuit!
A plug is not supplied with this machine. See below for
the recommended plug type for this machine.
If you are unsure about the wiring codes in your area
or you plan to connect your machine to a shared cir
-
cuit, you may create a fire or circuit overload hazard—
consult a qualified electrician to reduce this risk.
We do not recommend using an extension cord; however,
if you have no alternative, use the following guidelines:
Use a cord rated for Standard Service (S).
Do not use an extension cord longer than 50 feet.
Ensure that the cord has a ground wire and pin.
Use the gauge size listed below as a minimum.
Extension Cords
Operating Voltage Amp Draw Min. Circuit Size Recommended Plug Extension Cord
220V Single-Phase 5 Amps 15A NEMA 6-15 (not incl.) 14 Gauge
Figure 1. 6-15 plug and receptacle.
6-15P 6-15R
Electrical Specifications
The machine must be properly set up before it is
safe to operate. DO NOT connect this machine to the
power source until instructed to do so in the "Test
Run" portion of this manual.