Tekkeon MP3450-10 Battery Charger User Manual


 
6
Connect the Power Output Cord
1. Plug the large end of the power output cord into the DC OUT jack on the end of myPower ALL Plus.
The 5V voltage indicator will turn on to indicate that the voltage is set to the lowest setting.
(If you have previously selected a voltage, the voltage selection will be returned to the lowest setting.)
Adjust the Voltage Level
1. Locate the voltage specification for your portable device. This can be found
on the device power adapter label or device specification label which
typically is found on the bottom of the unit.
(If available, use the voltage specification shown on the power adapter.)
2. With the voltage lock in the unlocked position (switched right to UNLOCK),
set the voltage output to the voltage selection that is equal to or one
increment higher than the voltage identified for your device. To do this,
press the voltage selector until the voltage indicator turns on under the
appropriate voltage selection (5, 6, 7.5, 9, 12, 14, 16, 19). For example, if
your device requires 6V, set the voltage to 6. If your device requires 7.2V,
set the voltage to 7.5.
CAUTION: It is important to set the voltage selector NO MORE than one step higher than the voltage
requirement for the portable device as an incorrect setting may prevent myPower ALL Plus from working
with your device, or may harm your device in the rare instance that the device accepts the higher voltage.
However, for all devices, adjusting the voltage ONLY one step higher than required will not harm the
device.
3. Slide the voltage lock to the locked position (switched left to LOCK). This will prevent you from
accidentally selecting a different voltage while your device is connected.
4. To change the voltage, slide the voltage lock to the unlocked position (UNLOCK), and select a new
voltage. Be sure to relock the voltage.
Sample Power Adapter Label
MP3450_ug_0507_rev3_r1 6/6/07 10:08 AM Page 6