Wagner SprayTech 292003 Paint Sprayer User Manual


 
1
Power cord ground must remain intact. Do
not clip off ground pole on plug to fit a non-
grounded socket. Static build up will result
which may cause an explosion.
WARNING
Figure 4
SET-UP
SET-UP VM 200 POWER PACK:
1. GM 2000 EAC Socket Outlet
2. Ground Connection Knob
3. Fuse
4. On/Off Switch
5. On/Off Indicator Lamp (Green)
6. High Voltage Indicator Lamp (Red)
7. Grounding Cable
8. Ground Washer
9. GM 2000 EAC Connecting Cable
Step 1: Attach the grounding cable (7). Remove the ground
connection knob (2) and the ground washer (8). Put the ring
terminal end of the grounding cable on the grounding stud
and replace the ground washer (8) and the ground connec-
tion knob (2) securely. The end of the grounding cable with
the spring clip is to be attached to the object being sprayed.
Step 2: Attach the GM2000 EAC Connecting Cable (9) to
the Socket Outlet (1) on the Power Pack. Secure the cable
in place by screwing the nut onto the threads of the power
pack cable receptor.
Step 3: Plug power cord into a grounded 110 volt outlet.
POWER PACK
OPERATION
1. Set the VM 200 Power Pack Switch to the “I” position
(the green light turns on)
2. Adjust the fluid pressure to achieve maximum atomi-
zation.
3. If air assist is used, adjust air pressure regulator
between 10 & 30 psi.
4. Be sure all items within the spray area are well grounded
— Refer back to Warnings — Electrostatic arcing may
cause fire/explosion.
5. Test spray pattern and finish on a sample surface.
Keep the spray 8 - 12 inches away from the work
surface. Readjust fluid and/or air pressure to achieve
the optimum atomization and spray pattern.
6. Use the Air Adjustment Knob (located at rear of the
spray gun) to control the volume of air. For additional
fine tuning rotate tip nut. (Round tip only).
7. For best results, move the entire arm while spraying,
not just the wrist.
8. When Power Pack is turned on and the trigger on the
spray gun is pulled, both the green light and the red
light will be lit. The red light indicates the high voltage
is on.
9. The electrostatic On/Off Switch is to be turned off
when spraying into corners. With this switch in the “Off”
position, the red light on the Power Pack will not be lit.
(If the red light is lit with the electrostatic switch in the
“Off” position, DO NOT USE - TAKE TO AN AUTHOR-
IZED SERVICE CENTER FOR REPAIR.)
10. Lock the trigger on the spray gun after each use by
turning the trigger lock knob (located at the rear of the
spray gun) all the way to the right until it stops.
NOTE: The GM2000 EAC spray gun has a two-
stage trigger:
1. Pulling the trigger part way - Only the air is on.
2. Pulling the trigger all the way - Both air and fluid
are on.
10
2
1
3
4
5
6
9