Wagner SprayTech 292003 Paint Sprayer User Manual


 
1
14
Problem
• No green light on Power Pack
• Gun on-off switch performing
opposite.
• No red light on Power Pack.
• Spray pattern not even;
unsymmetrical or poor atomization.
• Spray pattern is correct, but there is
no wraparound.
• Dead outlet.
• Fuse blown.
• Not plugged in.
• Faulty circuit board.
• Defective switch.
• Cable from gun to Power Pack
loose or not connected.
• Cable from gun to Power Pack
defective.
• Blown fuse.
• If the trigger on the gun is pressed
and the above causes have been
checked and remedied and there is
still no high voltage, then the high
voltage generator or Power Pack
need service.
• Plugged spray tip.
• Worn or faulty tip.
• Paint too thick.
• Uneven air distribution at tip nut.
• Object not grounded.
• Cable not fitted properly.
• Cable faulty.
• High voltage generator
• Power Pack is turned off.
• Gun on/off switch is off.
• Fluid pressure too high.
• Air pressure too high.
• Electrode dirty or damaged.
• Live outlet.
• Replace fuse.
• Plug in.
• Take to Authorized Service Center.
• Take to Authorized Service Center.
• Tighten power cable.
• Replace power cable.
• Check fuse; replace if necessary.
• Take to Authorized Service Center
• Clean tip.
• Replace tip.
• Thin paint.
• Clean all air passages.
• Check ground.
• Check connection.
• Replace cable.
• Replace.
• Turn on.
• Turn on.
• Reduce fluid pressure.
• Reduce air pressure.
• Clean or replace.
Cause Solution
TROUBLESHOOTING