DO NOT use the router
table unless it is firmly
mounted to a stable work surface.
Failure to securely mount the router
table could lead to serious personal
injury and/or property damage.
Secure router table to the work surface
using wood screws or sheet metal
screws and washers (not provided)
through the holes provided. There are a
total of 8 mounting holes. See Figure
12.
WARNING
Introduction
A conveniently located Switch Box
allows the operator to:
• turn the router ON and OFF from the
front of the table
• simultaneously operate other devices
such as a light or a vacuum
It also features a resettable, internal
circuit breaker that protects your
equipment against overloads. See
Figure 13.
Figure 12
P
U
L
L
O
N
P
U
S
H
O
F
F
R
E
S
E
T
O
U
T
L
ET
S
Electrical Hookup
Proper grounding diverts potentially
dangerous electricity away from the
operator. The switch box is intended for
use with a three-prong, grounded outlet.
(See Figure 14.) The switch box's
electrical cord features an equipment-
grounding connector and a grounding
plug. Insert the plug into an
accommodating outlet that conforms to
all local electrical codes and the
National Electric Code (NEC).
Figure 13
Figure 14
reset button
SECURING THE ROUTER TABLE
SWITCH BOX