Xantech D5XH Router User Manual


 
08905154A - 18 -
USB Port (USB IN)
The USB IN port is designed to allow upgrades to the D5XH’s firmware.
AC Power Connector
Connect the supplied cord from the AC Power Connector into a properly grounded electrical outlet.
System Expansion
The D5XH is capable of supporting up to four sources to up to six zones. The system may be
expanded in two ways:
Local Sources
Adding Zones (Additional D5XH chassis)
Local Sources
Each zone of a D5RH/D5XH-based system can have its own “Local” source connected directly to the
zone’s D5KP Amplified Keypads using a D5IP Source Input Wall Plate. A source connected to a
D5KP is accessible from the zone in which it is connected. It is NOT AVAILABLE to the other zones
of the system. Both audio and IR control capabilities are available to Local Sources through the
D5KP. A zone may have a maximum of one Local Source.
D5IP Source Input Wall Plate
A D5IP Source Input Wall Plate is required to add a Local Source to a zone. The wall plate has audio
and IR connections similar to the SOURCE INPUT of the D5RH. A run of Cat-5 terminated to T-568A
standard (see Figure 3-3, page 12) is required between the D5KP Amplified Keypads and the location
designated for the D5IP. Connections between a source component and the D5IP are detailed in
Figure 3-7, Figure 3-8 and Figure 3-9, while connections between the D5IP and the D5KP Amplified
Keypads are detailed in Figure 3-10.
Figure 3-7: Local Source to D5IP Connections – Analog
NOTE: Be sure the RCA/OPT/COAX switch is ‘up’ and set to ‘RCA’.