Xantrex Technology 20A12V Battery Charger User Manual


 
Troubleshooting
975-0401-01-01 3–13
Troubleshooting
In the event that you have a problem with your Truecharge™
2 Battery Charger, the following tables will help you to
identify the problem and offer possible solutions to the
problem.
Symptom
Indicator LEDs do not illuminate when charger is connected to an AC
power source.
Symptom
The initial power up display test is not performed upon connection of
battery or batteries.
Possible Cause Solution
No power at AC source
Defective AC wiring or
switches/breakers
Ensure that power is available at charger AC
input and it is within acceptable range.
Wiring must be inspected and replaced by a
qualified installer.
Possible Cause Solution
Truecharge™ 2 Battery Charger
does not detect battery for one
of following reasons:
poor connection
reverse polarity connection
(blown fuse)
damaged wiring
open DC breaker or external
fuse
Check quality of battery connection and
wires.
Ensure correct polarity (negative connected
to negative, positive connected to positive).
In case there is an accompanying fault,
check the type of fault from Table 3-1,
“Interpreting Fault and Warning Indicators”
on page 3–4.