Xantrex Technology 815-2524-02 Battery Charger User Manual


 
975-0697-01-01 39
Installing the Inverter/Charger
This guide for use by qualified personnel only.
Step 8: Testing Your Installation
There are several tests to be performed to verify that the installation
is successful. These tests will verify that:
the Freedom SW 230V works in invert mode
the Freedom SW 230V works in charge mode
the Freedom SW 230V works in AC bypass mode
If any of the tests fails at any point, go to “Step 7: Performing
Checks Prior to Initial Start-Up” on page 38 and go through the
checklist again to check against the installation. Perform the tests
again. If any test fails again, see the troubleshooting section in the
Freedom SW 230V Sine Wave Inverter/Charger Owner’s Guide.
Testing in Invert Mode
To test the Freedom SW 230V in invert mode, using a 100 watt
light bulb as the test load:
1. Close the DC disconnect switch or the DC circuit breaker to
supply DC power to the Freedom SW 230V.
Wait for all the lights on the front panel to flash on and off,
indicating that the unit has successfully initialized (10 to 30
seconds).
If the light does not come on, make sure the voltage at the DC
terminals on the Freedom SW 230V is correct, as described in
“Step 7: Performing Checks Prior to Initial Start-Up” on page 38.
2. After initialization, observe that none of the lights on the front
panel should remain illuminated.
ELECTRICAL SHOCK HAZARD
The Inverter Enable button on the Freedom SW 230V and the optional
accessories do not disconnect DC or AC input power to the Freedom SW
230V.
Failure to follow these instructions can result in death or serious
injury.
Figure 15 Freedom SW 230V Front Panel
XANBUS INTERFACE STACKING
FREEDOM SW INVERTER/CHARGER
CLEAR FAULT
RESET
INVERTER
ENABLE
INVERTER
ENABLED
AC IN FAULT
GEN
SUPPORT
CHARGING WARNING
Freedom SW 3K2K 230V InvChg Install Guide.book Page 39 Friday, June 20, 2014 9:11 AM