Operation
3–2 975-0251-01-01
Freedom 10 Power Switch
The power switch is located on the front panel of the Freedom 10. This switch
controls
ON/OFF and RESET for the inverter. Expect a 3-second delay when the
power switch is turned
ON before the unit is activated.
If installed with the remote control panel, the power switch on the unit itself
should be left in the
OFF position.
If the unit is connected to external AC power, the power switch may be turned off,
but the battery charger will continue to function. The internal transfer switch will
continue to be engaged with the switch off and AC power will be available at the
output of the unit. If AC power is removed, the unit will not come on as an
inverter.
Remote Control Panel
12 V Models
The remote control panel provides LED bar graphs that show system status,
battery voltage, and current in both inverter and charge modes. For more
information about this remote, refer to its owner’s manual.
Figure 3-1
Freedom 10 Power Switch
Important:
The power switch controls the inverter function. Placing the switch in the
OFF position disables the inverter and connects mains to the output.
Figure 3-2