Yamaha generator Welding System User Manual


 
18
Battery Charging
TIP
9 The generator DC rated voltage is 12V.
9 Start the engine first, and then connect the gener-
ator to the battery for charging.
9 Before starting to charge the battery, make sure
that the DC protector is turned on.
1 Red wire
2 Black wire
1. Start the engine.
2. Connect the red battery charger lead to the posi-
tive (+) battery terminal.
3. Connect the black battery charger lead to the neg-
ative (-) battery terminal.
4. Turn the economy control switch off to start battery
charging.
9 Be sure the economy control switch is turned
off while charging the battery.
9 Be sure to connect the red battery charger lead
to the positive (+) battery terminal, and connect
the black lead to the negative (-) battery termi-
nal. Do not reverse these positions.
9 Connect the battery charger leads to the bat-
tery terminals securely so that they are not dis-
connected due to engine vibration or other dis-
turbances.
9 Charge the battery in the correct procedure by
following instructions in the owners manual
for the battery.
9 The DC protector turns off 2 automatically if
current above the rated flows during battery
charging.
To restart charging the battery, turn the DC pro-
tector on by pressing its button to ON 1.If
the DC protector turns off again, stop charging
the battery immediately and consult a Yamaha
dealer.
1 ON
2 OFF
NOTICE
762-040
1
2
6v 6v
12v
762-041
1
2
7DK-052
7DK-9-10 09.1.27 1:46 PM Page 18