04 - 26 1st Analog Input Frequency Gain Unit: 0.01
04 - 27 2nd Analog Input Frequency Gain Unit: 0.01
04 - 28 3rd Analog Input Frequency Gain Unit: 0.01
04 - 29 4th Analog Input Frequency Gain Unit: 0.01
Settings 0.00~160.00Hz Factory Setting: 0.00
These parameters divide output frequency into several sections. (Refer to Pr.04-22).
04 - 30 1st Output Frequency Gain Unit: 0.1
04 - 31 2nd Output Frequency Gain Unit: 0.1
04 - 32 3rd Output Frequency Gain Unit: 0.1
Settings 0.0~200.0% Factory Setting: 100.0
These parameters set output frequency gain. We can select the functions of 21st to 23rd via
multi-function terminal. When the multi-function terminal is active, output frequency multiplies a
gain, i.e. output frequency H=F*(Pr.04-30/04-31/04-32).