A SERVICE OF

logo

Unpacking and Assembly 1-15
29. Install the five reservoirs.
You may want to wear gloves during this procedure to pro-
tect your hands from pigment ink stains.
Place the reservoir into the wire rack. Match the color or
cleaning solvent label on the reservoir with the corre-
sponding label on the printer.
Remove the packing material from the ink level floats
inside the ink buckets.
Unscrew the plastic seal on the hook-shaped tube
attached to the filter. Discard, or retain for subsequent
use. A small amount of ink may come out of the tube
(ink will be present in the tubes from factory testing).
Connect the hook-shaped tube to the reservoir’s draw
tube, by pressing down until it seats with a click, and
turning the screw-on connector 3/4 to 1 turn. See
Fig. 1-7 below for location.
Note
Do not connect the hook-shaped tube to the air vent.
Doing so will result in no ink being drawn from the
reservoir.
Connect the float sensor cable from the reservoir to the
data port on printer. See Fig. 1-7 below for location.
Fig. 1-7. Installing the reservoirs