Anton/Bauer LOGIC Series Battery Charger User Manual


 
- 9 -
The large numbers 1, 2 or 3 indicate remaining
hours under current load (only one number will
display at any one time)
The pie chart numbers (15, 30, 45, or 60)
indicate remaining minutes under current load.
The InterActive Segment indicates a FULLY
CHARGED battery verified by charger
communication
Top BAR Solid: Indicates 75% - 96%
Top BAR Flashing: Indicates 50% - 75%
2
nd
BAR Solid: Indicates 37% - 50%
2
nd
BAR Flashing: Indicates 25% - 37%
3
rd
BAR Solid: Indicates 12% - 25%
3
rd
BAR Flashing: Indicates 12% - 0%
INTERACTIVE: Indicates 96% - 100%
Remaining Runtime
Hours
Minutes
LIQUID CRYSTAL DISPLAY (LCD)
The “RealTime” LCD display provides on-the-fly remaining run time
estimates in 15 minute increments as well as simultaneously providing
remaining capacity information using the traditional “Fuel Gauge” approach.
No special adapters or set up is required. RealTime automatically calculates
the load and displays capacity information and battery status at all times.
Fuel Gauge Bars