5. Apply pipe sealant tape to the
nipple on the standpipe.
6. Assemble the regulator and orient
as shown.
NOTE: Arrow indicates flow of
air. Make sure it is pointing in the
direction of air flow.
7. Reapply pipe sealant to outlet
pressure gauge and quick
connect.
8. Reassemble outlet pressure
gauge and quick connect. Orient
outlet pressure gauge to read
correctly. Tighten connect with
wrench.
To Replace Regulator
1. Release all air pressure from air
tank. See "To Drain Tank" in the
Maintenance section.
2. Set the On/Auto/Off lever to
"OFF" and unplug unit.
3. Using an adjustable wrench
remove the outlet pressure
gauge and quick connect from
the regulator.
4. Remove the regulator.
23 - ENG
A15256
Outlet Pressure Gauge
Quick
Connect
Regulator
Regulator
Nipple
Regulator
Arrow