Craftsman 919.728001 Air Compressor User Manual


 
27 - ENG
A15256
PROBLEM
CAUSE
CORRECTION
Motor will not
run.
Fuse blown, circuit breaker
tripped.
1. Check fuse box for blown
fuse and replace as
necessary. Reset circuit
breaker. Do not use a
fuse or circuit breaker
with higher rating than
that specified for your
particular branch circuit.
2. Check for proper fuse. You
should use a time delay
fuse.
3. Check for low voltage
conditions and/or proper
extension cord.
4. Disconnect the other
electrical appliances from
circuit or operate the
compressor on its own
branch circuit.
Motor overload protection
switch has tripped.
Let motor cool off and
overload switch will
automatically reset.
Tank pressure exceeds
pressure switch "cut-in"
pressure.
Motor will start automatically
when tank pressure drops
below "cut-in" pressure of
pressure switch.
Have checked by a Trained
Service Technician.
Check valve stuck open.
Remove and clean, or replace.
Possible defective motor
or starting capacitor.
Have checked by a Trained
Service Technician. Do not
operate the compressor in
the paint spray area. See
flammable vapor warning.
Paint spray on internal
motor parts.
Bleed the line by pushing the
lever on the pressure switch to
the "Off" position; if the valve
does not open, replace switch.
Pressure release valve on
pressure switch has not
unloaded head pressure.
Extension cord is wrong
length or gauge.
Check for proper gauge wire
and cord length.