Ratings
Frame Size
200-240Vac
+/- 10% 3Ø
(kW@220V,
hp@230V)
Normal Duty Heavy Duty
Max
Continuous
Current (A)
Motor
Power
(hp)
Typical
Output
(kW)
Max
Continuous
Current (A)
Motor
Power
(hp)
Typical
Output
(kW)
Order Code
0
SP0201 2.2 0.5 0.37 2.2 0.5 0.37
SP0202 3.1 0.75 0.55 3.1 0.75 0.55
SP0203 4 1 0.75 4 1 0.75
SP0204 5.7 1.5 1.1 5.7 1.5 1.1
SP0205 7.5 2 1.5 7.5 2 1.5
1
SP1201 5.2 1.5 1.1 4.3 1 0.75
SP1202 6.8 2 1.5 5.8 1.5 1.1
SP1203 9.6 3 2.2 7.5 2 1.5
SP1204 11 3 3 10.6 3 2.2
2
SP2201 15.5 5 4 12.6 3 3
SP2202 22 7.5 5.5 17 5 4
SP2203 28 10 7.5 25 7.5 5.5
3
SP3201 42 15 11 31 10 7.5
SP3202 54 20 15 42 15 11
4
SP4201 68 25 18.5 56 20 15
SP4202 80 30 22 68 25 18.5
SP4203 104 40 30 80 30 20
5
SP5201 130 50 37 105 40 30
SP5202 154 60 45 130 50 37
Frame Size
380-480Vac
+/- 10% 3Ø
(kW@400V,
hp@460V)
Normal Duty Heavy Duty
Max
Continuous
Current (A)
Motor
Power
(hp)
Typical
Output
(kW)
Max
Continuous
Current (A)
Motor
Power
(hp)
Typical
Output
(kW)
Order Code
0
SP0401 1.3 0.5 0.37 1.3 0.5 0.37
SP0402 1.7 0.75 0.55 1.7 0.75 0.55
SP0403 2.1 1 0.75 2.1 1 0.75
SP0404 3 1.5 1.1 3 1.5 1.1
SP0405 4.2 2 1.5 4.2 2 1.5
1
SP1401 2.8 1.5 1.1 2.1 1 0.75
SP1402 3.8 2 1.5 3 1.5 1.1
SP1403 5 3 2.2 4.2 2 1.5
SP1404 6.9 5 3 5.8 3 2.2
SP1405 8.8 5 4 7.6 5 3
SP1406 11 7.5 5.5 9.5 5 4
2
SP2401 15.3 10 7.5 13 7.5 5.5
SP2402 21 15 11 16.5 10 7.5
SP2403 29 20 15 25 15 11
SP2404 29 20 15 29 20
15
3
SP3401 35 25 18.5 32 25 15
SP3402 43 30 22 40 30 18.5
SP3403 56 40 30 46 30 22
4
SP4401 68 50 37 60 40 30
SP4402 83 60 45 74 50 37
SP4403 104 75 55 96 75 45
5
SP5401 138 100 75 124 100 55
SP5402 168 125 90 156 125 75
6
SP6401 205 150 110 180 150 90
SP6402 236 200 132 210 150 110
Frame Size
200-240Vac
+/- 10% 1Ø
(kw@220V,
hp@230V)
Normal Duty Heavy Duty
Max
Continuous
Current (A)
Motor
Power
(hp)
Typical
Output
(kW)
Max
Continuous
Current (A)
Motor
Power
(hp)
Typical
Output
(kW)
Order Code
0
SP0201 2.2 0.5 0.37 2.2 0.5 0.37
SP0202 3.1 0.75 0.55 3.1 0.75 0.55
SP0203 4 1 0.75 4 1 0.75
SP0204 5.7 1.5 1.1 5.7 1.5 1.1
SP0205 7.5 2 1.5 7.5 2 1.5
Frame Size
500-575Vac
+/- 10% 3Ø
(kW@575V,
hp@575V)
Normal Duty Heavy Duty
Max
Continuous
Current (A)
Motor
Power
(hp)
Typical
Output
(kW)
Max
Continuous
Current (A)
Motor
Power
(hp)
Typical
Output
(kW)
Order Code
3
SP3501 5.4 3 3 4.1 2 2.2
SP3502 6.1 5 4 5.4 3 3
SP3503 8.4 7.5 5.5 6.1 5 4
SP3504 11 10 7.5 9.5 7.5 5.5
SP3505 16 15 11 12 10 7.5
SP3506 22 20 15 18 15 11
SP3507 27 25 18.5 22 20 15
4
SP4603* 36 30 22 27 25 18.5
SP4604* 43 40 30 36 30 22
SP4605* 52 50 37 43 40 30
SP4606* 62 60 45 52 50 37
5
SP5601* 84 75 55 63 60 45
SP5602* 99 100 75 85 75 55
6
SP6601* 125 125 90 100 100 75
SP6602 144 150 110 125
125 90
Frame Size
500-690Vac
+/- 10% 3Ø
(kW@690V,
hp@690V)
Normal Duty Heavy Duty
Max
Continuous
Current (A)
Motor
Power
(hp)
Typical
Output
(kW)
Max
Continuous
Current (A)
Motor
Power
(hp)
Typical
Output
(kW)
Order Code
4
SP4601 22 25 18.5 19 20 15
SP4602 27 30 22 22 25 18.5
SP4603 36 40 30 27 30 22
SP4604 43 50 37 36 40 30
SP4605 52 60 45 43 50 37
SP4606 62 75 55 52 60 45
5
SP5601 84 100 75 63 75 55
SP5602 99 125 90 85 100 75
6
SP6601 125 150 110 100 125 90
SP6602 144 175 132 125 150 110
Notes: Select model on actual motor full load current. *The same model can be used on a
575V or a 690V supply, and has two different output ratings. For example: At Normal
Duty, SP4603 is suitable for a 30hp output motor on a 575V supply and a 40hp output
motor on a 690V supply. Can be used on IT supplies - all voltages, Grounded delta
supplies - all voltages except 690V
Normal Duty Heavy Duty
Suitable for most
applications, current
overload of 110% for 165
seconds is available. Where
motor rated current is
less than the drive rated
continuous current, higher
overloads are achieved.
Suitable for demanding applications, current overload of 175%
for 40 seconds is available for frame size 0 - 5 in closed-loop,
150% for 60 seconds in open-loop, and size 0 single phase
current overload is 150% for 60 seconds. For frame size 6 current
overload of 150% for 60 seconds is available in closed-loop
and 129% for 97 seconds in open-loop. Where the motor rated
current is less than the drive rated continuous current higher