Energizer PP355 Battery Charger User Manual


 
Page|8
ENERGIZERBATTERYMANUFACTURING
VERSION1.2
Figure7:ComparisonofPerformanceunderContinuousConstantPower
AAAA PP355
25 mW 24 88
50 mW 11 38
75 mW 6 24
100 mW 4 15
Continuous Discharge Time (hrs)
2.2‐‐PerformanceatOtherEnvironmentalConditions
WhenaZincAirbatteryisexposedtoanonstandardenvironment,adrivingforceforwatertransportin
oroutofthebatteryexists.Movementofwatervaporintothebatterycanfillvoidspaceintheanode
cavityun derhighhumidityenvironments,andmovementofwatervaporout
ofthebatterycandryout
theelectrolyteinlowhumidityenvironments.Eithersituationcandecreasebatteryperformanceover
time.
Understandingtheenvironmentalconditionsthata batterymightencounteriscriti calto estimating
batteryperformance.AstudywasdoneatEnergizertodeterminerealisticextremeconditionsfor
battery testing, using climate
data from 61 cities across the globe.Thesecities represent the major
marketsforbothdevicesandbatteries.Combinationsofdailymorningandafternoontemperatureand
humiditywerecompiledandanalyzedtodeterminereasonabletemperatureandhumidityextremes.
HotandHumidConditions
:
ZincAirPrismaticbatteriescantakeonwaterwhenexposedtohotandhumidconditions.Thiscanlimit
batteryperformance bytakingupvoidvolume intheairelectrodeandanodecompartment.At35°C
and 75% RH conditions, there isa driving force for watergain larger than 99% of
conditions seen in
combinedindoorandoutdoordatafromthetop61citiesglobally.ServicetestswiththePP355under
theseconditionsshowverygoodserviceevenat1hrperdayintermittency.
HotandAridConditions
:
Zinc Air Prismaticbatteries can losewater when exposed tohot and arid conditions whichcan limit
batteryperformancebydryingoutthebattery.Under35°Cand25%RHconditions,thereisadriving
forceforwaterlosslargerthan99%ofconditionsseenincombinedindoorandoutdoordata
fromthe
top61citiesglobally.ServicetestingwiththePP355attheseconditionsshowsverygoodserviceeven
at1hrperdayintermittency.