Exide S47-0079 Battery Charger User Manual


 
10
The 046-0371 control can provide an auto-refresh charge as long as the battery remains
connected to the charger if enabled. If AC power is lost during the wait period, the control resumes from
where it left off after power is restored. During the auto-refresh charge, the amp-hours and charge time
are added to the original charge. The refresh charge consists of 30 minutes at the equalize current. To
change the auto-refresh settings, refer to the programming section.
2.1.8 Viewing Charge Information
Additional charge information is available any time by pressing the INFO button. This information
is retained after the battery is disconnected until the next battery is connected. After 20 seconds the
display returns to the default display of amps and volts per cell. The following information can be viewed:
Parameter DISPLAY DESCRIPTION
Charger State XXXXXX
Message describing charger state.
Amps CHARGER DC AMPS
AA: xxxA
Charger current in amps.
Volts/Cell BATTERY V/C
VC: x.xxVC
Battery voltage in volts per cell (v/c).
Amp Hours ACCUMULATED AH
AH: xxxxAH
Amp Hours returned for the current (or last) charge cycle.
Charge Time CHARGE TIME
TC: xx:xxHM
Charge time for the current (or last) charge cycle in hours and minutes.
Percent Return % AH RETURNED
PR: xxx%
Percent of Amp Hours returned as a function of battery AH rating.
Voltage BATTERY VOLTS
VV: xx.xV
Total battery voltage in volts.
End Current CHARGE END AMPS
EA: xxxA
End current for the last charge cycle (current amps if charging)
End Voltage CHARGE END VOLTS
EV: x.xxVC
End voltage for the last charge cycle (current voltage if charging)
Software SOFTWARE VERSION
SW: x.xx
Control software version