Graco 16N655 Paint Sprayer User Manual


 
Operation
3A2308C 19
Shutdown and Cleaning
Flushing Sprayer
1. Engage trigger lock and put prime/pressure relief
valve UP to release pressure.
2. Turn pressure control knob to prime/clean position.
3. Remove cup from sprayer.
4. Remove lid from cup.
5. Remove material liner and lid from cup and properly
dispose. Properly dispose any excess material left
in the liner.
6. Insert a new liner into cup and fill 1/2 full with appro-
priate flushing fluid. Screw on lid and attach cup to
sprayer. Shake sprayer to move flushing fluid
around and clean all wetted areas inside cup.
NOTICE
Failure to properly clean sprayer after each use will
result in hardened materials, damage to the sprayer, and
the warranty will no longer be valid. Do not store solvents
other than mineral spirits in sprayer.
Do not spray solvents through the spray tip. Clean the tip
in a bucket of compatible solvent.
Keep spray area well-ventilated. Keep a good supply of
fresh air moving through the area.
NOTICE
Protect the internal parts of this sprayer from water.
Do not submerge the sprayer in cleaning fluid. Openings
in shroud allow cooling of mechanical parts and electron-
ics inside. If water or cleaning fluid gets into these open-
ings, the sprayer could malfunction or become
permanently damaged.
ti14994a
ti19347a
ti19350a
ti19357a
ti19360a
ti19363a
ti15000a
ti19352a
ti19365a