Graco 16N655 Paint Sprayer User Manual


 
Operation
3A2308C 9
Common Procedures
Trigger Lock
Follow the Pressure Relief Procedure whenever
you see this symbol.
Prime/Pressure Relief Valve Position
Pressure Relief Procedure
1. Engage trigger lock.
2. Put prime/pressure relief valve UP to release pres-
sure.
Spray Tip Position
Always engage the trigger lock when you stop spraying
to prevent the sprayer from being triggered accidentally
by hand, or if dropped or bumped.
ti14994a
Trigger Locked
Trigger Unlocked
ti14995a
(red ring is visible)
ti19374a
ti19350a
UP position
(For priming and releasing
DOWN position
(Ready to spray)
ti14999a
pump pressure)
ti19347a
ti19346a
Do not operate or spray near children. Do not aim the
sprayer at, or spray any person or animal. Keep hands
and other body parts away from the discharge. For
example, do not try to stop the paint flow with any part
of the body.
This sprayer builds up an internal pressure of 4000 psi
during use. This equipment stays pressurized until
pressure is manually relieved. To help prevent serious
injury from pressurized fluid, such as skin injection,
splashing fluid and moving parts, follow the Pressure
Relief Procedure when you stop spraying and before
cleaning, checking, or servicing the equipment.
Always perform Pressure Relief Procedure before
adjusting spray tip position.
ti19350a
ti14999a
ti19347a
Tip Forward
(SPRAY position)
Tip Reversed
(UNCLOG position)
ti14991a
ti14985a
ti15510a
ti19371a
ti19370a
ti15510a