7. Disengage trigger lock, turn sprayer upside-down
and trigger for approximately 15 seconds to
recirculate material.
8. Reverse tip to UNCLOG position. Put prime/pres-
sure relief valve DOWN to spray position and trigger
sprayer through tip into waste area for 1- 2 seconds.
9. Engage trigger lock. Put prime/pressure relief valve
in UP position.
10. Unthread tip/guard from sprayer and soak in appro-
priate flushing fluid.
11. Remove cup and properly dispose contaminated
fluid.
12. Refill liner 1/2 full. Disengage trigger lock, turn
sprayer upside-down and trigger sprayer for
approximately 15 seconds to recirculate material.
13. Put prime/pressure relief valve DOWN to spray
position. Spray the remaining amount of cleaning
fluid through the front of the sprayer.
14. If sprayer is not completely clean, repeat steps 11
and 12.
15. Engage trigger lock and put prime/pressure relief
valve UP to release pressure.
16. Remove material liner and lid and properly dispose.
Properly dispose used fluid.
17. Clean Spray Tip/Guard assembly with clean flush-
ing fluid. Use a soft brush to loosen and remove
dried material if needed.
To avoid serious injury or damage to equipment, do not
expose the sprayer electronics to flushing solvents.
Keep sprayer at least 10 in. above the rim of the con-
tainer when flushing.
Keep spray area well-ventilated. Keep a good supply
of fresh air moving through the area. When flushing
with solvents, always ground the sprayer and waste
container.
ti14994a
ti19374a
ti19798a
ti14995a
ti19346a
ti19366a
ti19370a
ti19350a
ti19347a
ti19386a
ti19385a
ti19374a
ti19358a
ti19346a
ti19404a
ti19350a
ti19347a
ti19385a
ti19344a