Graco 16N655 Paint Sprayer User Manual


 
Operation
8 3A2308C
Sprayer Status Indicator
*NOTE: The sprayer status indicator light is visible for 10 seconds after the trigger is released.
No light Normal operation. No action required.
Solid Red
Battery is too hot. Unit will
shut down until battery has
cooled.
Change battery.
Allow battery to cool.
Liquid has contacted control
board.
Allow unit to dry.
Flashing Red
Motor is too hot and will shut
down if heavy use continues.
Unit will shut down until motor
has cooled.
Increase tip size.
Turn down pressure.
Let unit cool down.
Solid Yellow
Battery is low or
battery is too cold.
Charge battery.
Warm up battery.
Flashing Yellow
High pressure signal. Gun will
shut down after 1.5 seconds.
Turn pressure control
counter-clockwise to reduce
pressure.
Increase tip size.
Material is too thin--do not thin
as much.
Solid red and solid yellow Locked motor.
Bring sprayer in to service cen-
ter for diagnostics.
ti19361a
Red
Yellow