Graco 262906 Paint Sprayer User Manual


 
Cleanup
332161A 11
Cleanup
1. Perform Relieve Pressure Procedure, page 6.
2. Remove guard and Spray Tip. For additional infor-
mation, see gun manual.
3. Remove siphon tube set from paint. Wipe excess
paint off outside of tubes.
4. Place siphon tube in flushing fluid. Use water for
water base paint and mineral spirits for oil base
paint. Place drain tube in waste pail.
5. Turn prime valve horizontal.
6. Hold gun against paint pail. Take trigger safety OFF.
Trigger gun and increase pressure until the pump
runs steady and flushing fluid appears.
7. Stop triggering gun. Move gun to waste pail, hold
gun against pail, trigger gun to thoroughly flush
system.
8. While continuing to trigger gun, turn prime valve
down. Then, release gun trigger. Allow flushing fluid
to circulate until fluid coming out of drain tube is
clear.
9. Raise siphon tube above flushing fluid.
10. Close drain valve. Trigger gun into flushing pail to
purge fluid from hose.
This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury from
pressurized fluid, such as skin injection, splashing
fluid and moving parts, follow the Pressure Relief Pro-
cedure when you stop spraying and before cleaning,
checking, or servicing the equipment.
ti20408a
Flush
Waste
ti2756b
ti20407a
1/4 Turn
ti20418a
Waste
ti2599a
ti20406a
ti10744a
Flush
ti20407a
ti2599c