Installation
AirAir
Air
SupplySupply
Supply
LineLine
Line
To reduce the risk of electric shock, the air supply
hose must be electrically connected to a true earth
ground. UseUse
Use
onlyonly
only
GracoGraco
Graco
GroundedGrounded
Grounded
AirAir
Air
SupplySupply
Supply
Hose.Hose.
Hose.
1. See Fig. 10. Use the Graco Grounded Air Supply
Hose (AH) to supply air to the gun. The gun air
inlet tting has a left-hand thread. The air supply
hose ground wire (AG) must be connected to a
true earth ground. Do not connect the air supply
hose to the gun air inlet yet.
2. Install an air line lter/water separator (AF) on the
gun air line to ensure a dry, clean air supply to the
gun. Dirt and moisture can ruin the appearance
of your nished workpiece and can cause the
gun to malfunction.
3. Install bleed-type air regulators (PR, GR) on
the pump and gun air supply lines to control air
pressure to the pump and gun.
Trapped air can cause the pump to cycle
unexpectedly, which can result in serious
injury, including splashing uid in the eyes or
on the skin. Do not operate the equipment
without the bleed-type air valve (BV) installed.
4. Install a bleed-type air valve (BV) on the pump
air supply line. The bleed-type air valve (BV) is
required in your system to shut off air to the pump
and relieve air trapped between the valve and
the pump after the air regulator is shut off. Install
an additional bleed-type air valve on the main air
line (MA) to isolate the accessories for servicing.
5. Install an air bleed valve (BV) on each gun air
supply line to shut off air to the gun(s) and relieve
air trapped between the valve and the gun after
the air regulator is shut off.
FluidFluid
Fluid
SupplySupply
Supply
LineLine
Line
1. Blow out the uid line (FL) with air and ush it
with solvent. Use solvent which is compatible
with the uid to be sprayed. Do not connect the
uid supply line to the gun uid inlet yet.
2. Install a uid regulator (FR) on the uid line to
control uid pressure to the gun.
3. Install a uid lter (FF) near the pump outlet, to
remove particles and sediment which could clog
the spray nozzle.
To reduce the risk of serious injury, including
splashing uid in the eyes or on the skin, do
not operate equipment without the uid drain
valve (FD) installed.
4. The uid drain valve (FD) is required in your
system to assist in relieving uid pressure in the
displacement pump, hose, and gun. Triggering
the gun to relieve pressure may not be sufcient.
Install a drain valve close to the pump's uid
outlet.
163A2494D