Graco 3A2494D Staple Gun User Manual


 
Operation
OperationOperation
Operation
PressurePressure
Pressure
ReliefRelief
Relief
ProcedureProcedure
Procedure
1. Turn OFF (O) the ES On/Off switch.
2. Turn off the air bleed valves to the uid source
and to the gun.
3. Trigger the gun into a grounded metal waste
container to relieve the uid pressure.
4. Open the pump drain valve, having a waste
container ready to catch the drainage. Leave
the pump drain valve open until you are ready
to spray again.
5. If the nozzle or hose is completely clogged or
pressure is not fully relieved, slowly loosen the
hose end coupling. Now clear the nozzle or hose.
StartupStartup
Startup
Follow all steps under Gun Setup Checklist, page 18.
ShutdownShutdown
Shutdown
1. Flush the gun, see Flushing, page 28.
2. Follow the Pressure Relief Procedure, page 27.
3. Hang the gun from its hook, with the nozzle
pointing down.
3A2494D
27