Graco 3A2494D Staple Gun User Manual


 
Repair
AirAir
Air
CapCap
Cap
andand
and
NozzleNozzle
Nozzle
ReplacementReplacement
Replacement
NOTICENOTICE
NOTICE
Trigger the gun while removing the nozzle to help
drain the gun and prevent any paint or solvent left
in the gun from entering the air passages.
1. See Prepare the Gun for Service, page 37.
2. Remove the retaining ring (6) and air cap (5).
3. Trigger the gun while removing the uid nozzle
(4) assembly with the multi-tool (41).
The nozzle contact ring (4a) is a conductive
contact ring, not a sealing o-ring. To reduce
the risk of sparking or electric shock, do not
remove the nozzle contact ring (4a) except to
replace it and never operate the gun without
the contact ring in place. Do not replace the
contact ring with anything but a genuine Graco
part.
NOTICENOTICE
NOTICE
Use non-silicone grease, Part No. 111265, on
the small o-ring (4b). Do not over-lubricate. Do
not lubricate the conductive contact ring (4a).
4. Make sure the conductive contact ring (4a) and
the small o-ring (4b) are in place on the nozzle
(4). Lightly lubricate the small o-ring (4b).
NOTE:NOTE:
NOTE:
The conductive contact ring (4a) may
show some wear at the point where it makes
contact with the barrel pin. This is normal and
does not require replacement.
5. Make sure the electrode needle (3) is nger-tight.
6. Trigger the gun while installing the uid nozzle
(4) with the multi-tool (41). Tighten until the uid
nozzle seats in the gun barrel (1/8 to 1/4 turn
past hand-tight).
7. Install the air cap (5) and retaining ring (6). Make
sure the u-cup (6a*) is in place with the lips facing
forward.
8. See Test Gun Resistance, page 31.
Figure 20 Air Cap and Nozzle Replacement