Table Tilt Calibration
When the table is perpendicular to the sanding
disc, the scale should read 0˚. If not, follow this
procedure.
Tools Needed:
90° Square ........................................................ 1
45° Square ..........................................................
Phillips Head Screwdriver .................................. 1
Hex Wrench 5mm .............................................. 1
3. Loosen lock handles, then adjust 90° stop
screw (see Figure 26) until table angle is
perfectly perpendicular to disc.
4. Tighten lock handles while holding table in
place.
Figure 26. Squaring table.
90°
Stop
Screw
45°
Stop
Knob
6. Recheck scale accuracy with square.
Figure 27. Scale pointer screw location.
Scale
Pointer
5. Loosen degree scale pointer screw (see
Figure 27), adjust pointer to 0˚, then retight-
en screw.
Calibrating Table Tilt
1. DISCONNECT MACHINE FROM POWER!
2. Loosen lock handles and allow table to rest
on 45° stop knob.
3. Set one edge of a 45° square on table sur-
face and other edge against face of disc.
4. Adjust 45° stop knob (shown in Figure 26)
until table angle is exactly 45° to disc, then
tighten hex nut under 45° stop knob against
sander frame.
Calibrating 45° Stop
1. DISCONNECT MACHINE FROM POWER!
2. Set one edge of a try square or 90° square on
table surface and the other edge against face
of disc, as shown in Figure 26.
Note: Although this can be done with the
sandpaper installed, it is more precise with-
out it.
Hex Nut