Page 12 For technical questions, please call 1-800-444-3353. SKU 67450
OPERATING INSTRUCTIONS
Read the ENTIRE IMPORTANT
SAFETY INFORMATION
section at the beginning of this
manual including all text under
subheadings therein before set up
or use of this product.
Inspect tool before use, looking
for damaged, loose, and missing
parts. If any problems are found,
do not use tool until repaired.
Work Piece and Work Area Set Up
Designate a work area that is clean and 1.
well-lit. The work area must not allow
access by children or pets to prevent
distraction and injury.
Route the air hose along a safe path to 2.
reach the work area without creating a
tripping hazard or exposing the air hose
to possible damage. The air hose must
be long enough to reach the work area
with enough extra length to allow free
movement while working.
There must not be hazardous objects 3.
(such as utility lines or foreign objects)
nearby that will present a hazard while
working.
Contact Safety Trip (Bump Fire)
Mechanism Denition
The RED TRIGGER enables a contact
the Safety Nosepiece is pressed against the
workpiece and the trigger is pulled. It should
OR if the safety is lifted and pressed against
the workpiece again. The Tool should not
against an object. Contact safety trip /
bump re should only be enabled and
used by skilled operators who are aware
of the hazards and use proper, safe work
practices.
Contact Safety Trip (Bump Fire)
Mechanism Testing Procedure
TO PREVENT
SERIOUS INJURY
FROM ACCIDENTAL
OPERATION:
Empty the tool before this
procedure. Point the tool at a
piece of scrap wood when
testing.
Disconnect the tool from the air supply.1.
Empty the magazine of fasteners.2.
Check that the Trigger and the Safety 3.
Nosepiece move freely, without sticking.
Connect the air supply to the tool and 4.
set within the Operating Air Pressure
Test the tool by pressing the Safety 5.
Nosepiece against the workpiece
without pulling the Trigger. The tool
must not cycle (re).
stop immediately and take the tool to a
Hold the tool away, or off of the 6.
workpiece. The Safety Nosepiece
should return to its original position.
Squeeze the Trigger. The tool must
not cycle (re).
stop immediately and take the tool to a
Press the Safety Nosepiece against 7.
the workpiece and squeeze the Trigger.
The tool must cycle (re) only once.
Release the trigger and squeeze it
again. The tool must cycle (re)
again only once. With the Trigger held,
carefully lift the tool and press it against
REV 10g