Troubleshooting
Problem Possible Causes Likely Solutions
Compressor does
not start or restart
Incorrect power supply.1.
No power at outlet. 2.
Power cord not plugged in 3.
properly.
Thermal overload switch 4.
tripped or Compressor circuit
breaker tripped.
Building power supply circuit 5.
tripped or blown fuse.
Tank already pressurized.6.
Cord wire size is too small or 7.
cord is too long to properly
power compressor.
Compressor needs service.8.
Check that circuit matches compressor requirements.1.
Reset circuit breaker, or have outlet serviced by a 2.
qualied technician.
Check that cord is plugged in securely. 3.
Turn off tool. Turn off Compressor and wait for it to cool 4.
down. Press Reset Button. Resume operation.
Reset circuit or replace fuse. Check for low voltage 5.
conditions. It may be necessary to disconnect other
electrical appliances from the circuit or move the
compressor to its own circuit.
Fully bleed tank of air.6.
Use larger diameter or shorter extension cord or 7.
eliminate extension cord. See Recommended Wire
Gauge for Extension Cords in Safety section.
Have unit inspected by a qualied technician.8.
Compressor shuts
off automatically
before reaching full
pressure (Circuit
breaker trips)
Cold weather 1.
Extension cord usage.2.
Turn off tool. Press the Reset Button. Start 1.
Compressor in a heated area if temperatures drop
below 32ºF, or use SAE 10W non-detergent air
compressor oil instead of 30W.
Turn off tool. Press the Reset Button. Use without 2.
extension cord.
Compressor
hums, then shuts
off automatically
before reaching full
pressure (Circuit
breaker trips)
Cold weather. 1.
Extension cord usage. 2.
Engine too hot.3.
Press the Reset Button, then, start Compressor in a 1.
heated area if temperatures drop below 32ºF, or use
SAE 10W non-detergent air compressor oil instead of
30W.
Press the Reset Button. Use without extension cord. 2.
Wait for engine to cool and unit will start automatically.3.
Compressor builds
pressure too slowly
Incorrect power supply.1.
Crankcase overlled with oil or 2.
oil too thick.
Working environment too cold. 3.
Safety valve needs service. 4.
Loose ttings.5.
Check that circuit matches compressor requirements.1.
Drain oil and rell to proper level with recommended 2.
oil.
Move unit to a warmer location. Check that 3.
recommended oil is in crankcase.
Listen for air leaking from valve. If leaking replace with 4.
identical valve with same rating.
Reduce air pressure, then check all ttings with a soap 5.
solution for air leaks and tighten as needed. Do not
overtighten.
Compressor not
building enough air
pressure
Filters need cleaning/replacing. 1.
Crankcase oil too thick. 2.
Check Valve needs service.3.
Compressor not large enough 4.
for job.
Loose ttings. 5.
Hose or hose connections not 6.
adequate.
High altitude reducing air 7.
output.
Check inlet and outlet lters. Clean and/or replace as 1.
needed.
Drain oil and rell to proper level with recommended 2.
oil.
Clean or replace, as needed.3.
Check if accessory SCFM is met by Compressor. If 4.
Compressor cannot supply enough air ow (SCFM),
you need a larger Compressor.
Reduce air pressure, then check all ttings with a soap 5.
solution for air leaks and tighten as needed. Do not
overtighten.
Replace with larger hose and/or hose connections. 6.
You may need a larger compressor if you are situated 7.
in a high altitude location.