HP (Hewlett-Packard) TI1681A Paint Sprayer User Manual


 
Installation
14 309293J
c. Connect the end of the tube (T) to the pump
fluid outlet fitting (Z).
245895 Agitator Kit
To add an agitator to the Graco isolation system, order
Part No. 245895. See page 67 for the kit parts list.
1. Discharge the system voltage (page 20).
2. Relieve the pressure (page 20).
3. Open the isolated enclosure door.
4. Remove the back of the control box (258).
5. Remove tube (A2) from elbow (282) at the air mani-
fold; see the tubing diagram on page 64. Install the
Y fitting (402) into the elbow. Install tubes (A2) and
(407) into the Y fitting. See F
IG. 11.. Route the agita-
tor tube (407) into the cabinet.
6. Replace the back of the control box (258).
7. Assemble the other parts of the kit as shown.
Secure the agitator with the setscrew (408).
8. Return the system to service.
Fig. 11. 245895 Agitator Kit
CAUTION
The Graco warranty is void if the spray gun is con-
nected to a non-Graco voltage isolation system or if
the gun is operated above 60 kV.
CAUTION
Factory Mutual approval is valid only when this gun is
used with Factory Mutual approved voltage isolation
systems.
401
406
403
404
406 (Ref)
407
402
TI2137A
Install tube A2 here
Connect to elbow (282)
inside control box (258)
408