Operation
Operating Checklist
Check the following list daily, before starting to operate the system, to help ensure you of safe, efficient operation.
All operators are properly trained to safely
operate an electrostatic waterborne air spray
system as instructed in this manual.
All operators are trained in the Pressure
Relief Procedure on page 20.
The electrostatics are turned off and properly
grounded according to the.Fluid Voltage Dis-
charge and Grounding Procedure on page
20 before any person enters the safety enclo-
sure, before cleaning, and before performing
any maintenance or repair.
The system is thoroughly grounded and the
operator and all persons entering the spray
area are properly grounded. See Grounding
on page 17.
Fluid Hose is in good condition with no cuts or
abrasions of the PTFE layer. Replace hose if
damaged.
Ventilation fans are operating properly.
Workpiece hangers are clean and grounded.
All debris, including flammable fluids and rags,
is removed from the spray area.
Only fluids with a flash point above 140°F
(60°C) and a maximum organic solvent con-
centration of 20%, by weight, may be in the
spray area.
All conductive objects in the spray area are
electrically grounded and the floor of the spray
area is electrically conductive and grounded.