HP (Hewlett-Packard) TI1681A Paint Sprayer User Manual


 
Operation
309293J 25
Shutdown
1. Discharge the system voltage (page 20).
2. Flush the spray gun. See page 26.
3. Relieve the pressure (page 20).
4. Hang the gun from its hook or place it in the acces-
sory holster, with the nozzle pointing down. Be sure
to keep the gun from grounding out.
Low Voltage Adjustment (Smart
Guns Only)
The ES HI/LO switch enables you to switch between full
voltage and a lower voltage output. The lower voltage is
factory set, but can be adjusted.
1. Set the ES HI/LO switch to LO.
2. Remove the LO VOLTAGE adjustment plug (53). Set
the desired voltage, using a small screwdriver to
slide switches 1 and 2 ON or OFF, according to
Table 4 . Also see F
IG. 15..
Fig. 15. Low Voltage Adjustment Switches
WARNING
Pressurized Equipment Hazard
To reduce the risk of an injury, follow the
Pressure Relief Procedure on whenever
you are instructed to relieve the pressure.
ti1276a
ti1276a
ti1288a
Table 4: Low Voltage Adjustment
12kV
ON ON 50
Factory Setting >ON OFF 40
OFF ON 35
OFF OFF 30
100%
KV
μα
0
ti1529a
53
12
ON
OFF