Hitachi C 10RA2 Saw User Manual


 
7
English
WARNING:Avoid electrical shock hazard. Never use this tool with a damaged or frayed electrical cord
or extension cord.
Inspect all electrical cords regularly. Never use in or near water or in any environment
where electric shock is possible.
GROUNDING INSTRUCTIONS
ALL GROUNDED, CORD-CONNECTED TOOLS: In the event of a malfunction or breakdown, grounding
provides a path of least resistance for electric current to reduce the risk of electric shock. This tool is equipped
with an electric cord having an equipment-grounding conductor and a grounding plug. The plug must be
plugged into a matching outlet that is properly installed and grounded in accordance with all local codes
and ordinances. Do not modify the plug provided - if it will not fit the outlet, have the proper outlet installed
by a qualified electrician. Improper connection of the equipment - grounding conductor can result in a risk
of electric shock. The conductor with insulation having an outer surface that is green with or without yellow
stripes is the equipment grounding conductor. If repair or replacement of the electric cord or plug is necessary,
do not connect the equipment-grounding conductor to a live terminal.
Check with a qualified electrician or service personnel the grounding instructions are not completely
understood, or if it doubt as to whether the tool is properly grounded.
Use only 3-wire extension cords that have 3-prong grounding plugs and 3-pole receptacles that accept the
tools plug. Repair or replace damaged or worn cord immediately.
Grounded, cord -connected tools intended for use on a supply circuit having a nominal rating less than 150
volts: This tool is intended for use on a circuit that has an outlet that looks like the one illustrated in Fig. A.
The tool has a grounding plug that looks like the plug illustrated in Fig. A. A temporary adapter, which looks
like the adapter illustrated in Fig. B and C, may be used to connect this plug to a 2-pole receptacle as shown
in Fig. B if a properly grounded outlet is not available. The temporary adapter should be used only until a
properly grounded outlet can be installed by a qualified electrician. The green-colored rigid ear, lug, and the
like, extending from the adapter must be connected to a permanent ground such as a properly grounded
outlet box.
GROUNDING METHODS
SAVE THESE INSTRUCTIONS
AND
MAKE THEM AVAILABLE TO
OTHER USERS OF THIS TOOL!
MINIMUM GAGE FOR CORD SETS
Total Length of Cord in Feet (Meter)
0 25 26 50 51 100 101 150
(0 7.6) (7.9 15.2) (15.5 30.5) (30.8 45.7)
Ampere Rating AWG
More Not More
Than Than
0 618161614
6 10 18 16 14 12
10 12 16 16 14 12
12 16 14 12 Not Recommended
Grounding Pin
Cover of Grounded
Outlet Box
Metal Screw
Adapter
Grounding Means
Fig. A Fig. B Fig. C