Hitachi NB616X Welder User Manual


 
15
Chapter 5 SETTING
5.3 Items regarding the feed back board of the inverter main body
Code Function name Setting range Initial data
Setting
on run
Change
mode on
run
A044 1
st
control method
00(VC) / 01(VP1.7power) / 02(Free V/f Setting)
/ 03(SLV) / 04(0Hz area SLV) / 05(V2)
00 - -
H001
Auto-tuning mode
selection
00(NOR : Invalid) / 01(NRT : not rotate)/ 02(AUT :
rotate)
00 - -
H002
1
st
motor constant
selection
00(Hitachi standard motor constant)/
01(Auto-tuning data)/
02(Auto tuning data with online auto-tuning)
00 - -
H003
1
s
t
motor capacity
selection
0.20 - 75.0(kW)
Setting on
forwarding
--
H004
1
s
t
motor pole
selection
2/4/6/8 (Poles) 4 - -
H005
1
s
t
motor speed
response setting
0.001 - 9.999 / 10.00 - 65.53 1.590
H006 1
st
stabilized factor 0. - 255. 100.
H020 1
st
motor R1 setting
0.000 - 9.999 / 10.00 - 65.53()
depends on
the motor
capacity
--
H021 1
st
motor R2 setting
0.000 - 9.999 / 10.00 - 65.53()
depends on
the motor
capacity
--
H022 1
st
motor L setting 0.00 - 99.99 / 100.0 - 655.35(mH)
depends on
the motor
capacity
--
H023 1
st
motor I
0
setting 0.00 - 99.99 / 100.0 - 655.35(A)
depends on
the motor
capacity
--
H024 1
st
motor J setting
0.000 - 9.999 / 10.00 - 99.99 /
100.0 - 9999.(kgm
2
)
depends on
the motor
capacity
--
H030
1
st
motor R1 setting
(Auto-tuning data)
0.000 - 9.999 / 10.00 - 65.53()
depends on
the motor
capacity
--
H031
1
st
motor R2 setting
(Auto-tuning data)
0.000 - 9.999 / 10.00 - 65.53()
depends on
the motor
capacity
--
H032
1
st
motor L setting
(Auto-tuning data)
0.00 - 99.99 / 100.0 - 655.35(mH)
depends on
the motor
capacity
--
H033
1
st
motor I
0
setting
(Auto-tuning data)
0.00 - 99.99 / 100.0 - 655.35(A)
depends on
the motor
capacity
--