Chapter 5 SETTING
(Note 1) : Please refer to the instruction manual of the inverter main body as to the setting
procedure.
(Note 2): When the over speed abnormal detection level (P026), the speed error over detection level
(P027) are set 0, the Abnormal detection data processing will be invalid.
(Note 3): Regarding the SJ-FB setting, there are some warning about what type of main body
combines with the SJ-FB which is written following list.
Main body of SJ300 Production No (MFG No) (Note 4)
No. Item
9 8 XXXXXXXXXXXX
9 9 XXXXXXXXXXXX
9 O XXXXXXXXXXXX
9 J XXXXXXXXXXXX
9 K XXXXXXXXXXXX
0 1 XXXXXXXXXXXX
others
1 Completion
delay time
setting for
orientation
(P018)
Range of setting: 0.00 - 9.99 (X10(sec))
(Example) In order to operate the completion
delay time setting for orientation for 1(sec).
Set P018 setting which is written below.
P018=1(sec)/10(sec) =0.10
Range of setting: 0.00 - 9.99 (X1(sec))
( Example) In order to operate the completion
delay time setting for orientation for 1(sec).
Set P018 setting which is written below.
P018=1(sec) / 1(sec)=1.00
2 Over speed
abnormal
detection
level
Range of setting: 0.0 - 150.0 (X100)
(Example) In order to operate the over speed
detection level at 66Hz while maximum
frequency is 60Hz. Set P026 setting which is
written below.
P026=66Hz / 60Hz=1.1
Range of setting: 0.0 - 150.0 (X1%)
(Example) In order to operate the over speed
detection level at 66Hz, while maximum
frequency is 60Hz. Set P026 setting which is
written below.
P026=66Hz / 60HzX100=110.0
(Note 4) Main body of SJ300 Production number (MFG No) is written main body of SJ300
specifications label. Refer to figure 5-2(1), figure 5-2(2) please.
Figure 5-2(1) position of specification
Figure 5-2 (2) Contents of specification label
Specifications label
Inverter model
Maximum applicable motor
Input ratings
Output ratings
Production number