Hitachi NB616X Welder User Manual


 
26
Chapter 7 FUNCTIONS
(Note 3) : N/D must be given as the ranges of 1/50 (N/D) 20.
(N: Electronic gear ratio numerator, D: Electronic gear ratio denominator)
(Note 4) : It depends on what type of main body combines with the SJ-FB, the setting
value conversion is different. Please refer to the (Note 3) of the “5.3 Items
regarding the feed back board of the inverter main body“.
Data setting of input-output terminals
Input-output terminal With terminal assignment Contents
Input
The pulse train position
command input permission
signal. (STAT)
Set ‘48’ to one of
C001C008
Pulse train position command input
is valid while ON.
Output
Positioning completion
signal.(POK)
Set ‘23’ to one of
C021C025
Output when it entered into the
positioning completion range
Set ‘48’ (the pulse train position command input permission signal (STAT)) to one of C001C008.
Pulse train position command input is valid only in the case that the STAT terminal is turned ON. In
the case that the STAT terminal is OFF or unestablished, pulse train position command input is
invalid.
Below the example of the proportion of the slave side turn number to the master side turn number
by the setting of P019P021 is shown. (Yet, the encoder pulse number of the master side and slave
side are same and be in the case of 1024 pulses. )
Position selection for electronic gear (P019) 01 (REF) 01 (REF) 00 (FB) 00 (FB)
Numerator of ration setting for electronic gear (P020) 1024 2048 1024 2048
Denominator of ratio setting for electronic gear (P021) 2048 1024 2048 1024
Slave side turn number to the master side turn number 1/2 2 2 1/2