Hobart Welding Products 2510 Welder User Manual


 
9OM-185 158
2. Installation
2.1 Specifications
Amps Input at Rated Output, 60 Hz, Single-Phase
Rated Output
Max. OpenCir-
cuit Voltage
200 V 230 V 460 V 575 V KVA KW
250 A at 28 VDC,
40% Duty Cycle
200 A at 28 VDC,
60% Duty Cycle
32 50
2.3*
44
2*
22
1*
18
0.8*
10
0.46*
7.7
0.13*
Wire Type and Diameter Wire Feed Speed Dimensions Weight
Solid Steel Stainless Steel Flux Cored 50670 IPM H: 37 in (940 mm) 198 lb
.023 .045 in
(0.6 1.2 mm)
.023 .035 in
(0.6 0.9 mm)
.030 .045 in
(0.8 1.2 mm)
(1.21.7 m/min) W: 19 in (483 mm)
D: 30-1/4 in (768 mm)
(89 kg)
* While idling
4 Minutes Welding 6 Minutes Resting
6 Minutes Welding 4 Minutes Resting
2.2 Duty Cycle and Overheating
Duty Cycle is percentage of 10 min-
utes that unit can weld at rated load
without overheating.
If unit overheats, thermostat(s)
opens, output stops, and cooling
fan runs. Wait fifteen minutes for
unit to cool. Reduce amperage or
voltage, or duty cycle before
welding.
Y Exceeding duty cycle can
damage unit and void
warranty.
Overheating
0
15
A or V
OR
Reduce Duty Cycle
Minutes
duty1 4/95 SB-150 215
40% Duty Cycle At 250 Amperes60% Duty Cycle At 200 Amperes