Hobart Welding Products 2510 Welder User Manual


 
13OM-185 158
2.9 Installing Wire Spool and Adjusting Hub Tension
ST-801 790
When a slight force is needed
to turn spool, tension is set.
9/16 in
Tools Needed:
Small Spool Adapter
2.10 Positioning Jumper Links
Ref. ST-801 789
Check input voltage available at
site.
1 Jumper Links Access Door
Open door.
2 Jumper Link Label
3 Input Voltage Jumper Links
Move jumper links to match input
voltage.
Close and secure access door.
Close door.
Tools Needed:
1
3/8 in
3
2
200 VOLTS
230 VOLTS
460 VOLTS
S-144 918-C
230 VOLTS
460 VOLTS
575 VOLTS
S-144 916-A