14 OM-185 158
2.11 Electrical Service Guide
S-0092J
Input Voltage 200 230 460 575
Input Amperes At Rated Output 50 44 22 17
Max Recommended Standard Fuse Or Circuit Breaker Rating In Am-
peres
80 70 35 25
Min Input Conductor Size In AWG/Kcmil 8 8 10 12
Max Recommended Input Conductor Length In Feet (Meters) 93 (28) 124 (38) 329 (100) 313 (95)
Min Grounding Conductor Size In AWG/Kcmil 8 8 10 12
Reference: 1996 National Electrical Code (NEC)
2.12 Selecting a Location and Connecting Input Power
Have only qualified persons make
this installation.
1 Rating Label
Supply correct input power.
Y Special installation may be
required where gasoline or
volatile liquids are present
see NEC Article 511 or CEC
Section 20.
ST-801 788
18 in (457 mm)
for airflow
Size and ratings must comply with ap-
plicable codes. Install conductors in
conduit or equivalent into a deener-
gized line disconnect device (see
Section 2.11).
GND/PE
Connect First
L1
L2
GND/PE