Honeywell 4820 Work Light User Manual


 
2 - 2
RS-232
The RS-232 Interface bar code is used when connecting to the serial port of a
PC or terminal. The following RS-232 Interface bar code also programs a car-
riage return (CR) and a line feed (LF) suffix, baud rate, and data format as indi-
cated below. It also changes the trigger mode to manual.
Wand Emulation Plug & Play
In Wand Emulation mode, the image scanner decodes the bar code then sends
data in the same format as a scanner image scanner. The Code 39 Format
converts all symbologies to Code 39.
The Same Code Format transmits U.P.C., EAN, Code 128 and Interleaved 2 of
5 without any changes, but converts all other symbologies to Code 39.
The Wand Emulation Plug & Play Code 39 Format
bar code below sets the
terminal ID to 61. The Wand Emulation Plug & Play Same Code Format bar
code sets the terminal ID to 64. These Plug & Play bar codes also set the
Transmission Rate to 25 inches per second, Output Polarity to black high, and
Idle State to high. (If you want to change the terminal ID
only
, without changing
any other image scanner settings, please refer to Programming the Interface -
Terminal ID Method on page 2-6.)
Option Setting
Baud Rate 115200 bps
Data Format 8 data bits, no parity bit, 1 stop bit
RS-232 Interface
Wand Emulation
Plug & Play
Same Code
Wand Emulation
Plug & Play
(Code 39 Format)