Case Specifications
TEMPERATURE DISCHG. TYPE DEFROST 115 V. ELECTRICAL CIRCUITS HUMIDITY
MODEL BTU AVG AIR T-STAT/ FAN SIZE FREQ. AIR AIR HUNIDITY
LENGTH REQ’D EVAP PROD DISC VELOC CUT IN NUMBER FAN & E E FANS RECEP- SWEEP SWEEP SYSTEM
APP. FT. TMP TMP TMP @FPM SETTINGS EVAP. COIL OF MOTORS QTY DURATION (STANDARD) LIGHTS TACLE FANS HEATER FANS
VGD Deli (Blower Coil)
4' Deli 750 20° 34° 25° 250 26° Forced Evap 4
1
/2" Axial 3 36 min. 54 1.83 15.0 36 1.04 [.16]
Air Air Sweep 4
1
/2" Axial 1 (4)
Humidity 3
1
/4” Axial 1
6' Deli 750 20° 34° 25° 250 26° Forced Evap 4
1
/2" Axial 4 36 min. 1.08 3.66 15.0 72 1.57 [.16]
Air Air Sweep 4
1
/2" Axial 2 (4)
Humidity 3
1
/4” Axial 1
8' Deli 750 20° 34° 25° 250 26° Forced Evap 4
1
/2" Axial 4 36 min. 1.08 3.66 15.0 1.08 2.09 [.16]
Air Air Sweep 4
1
/2" Axial 3 (4) s
Humidity 3
1
/4” Axial 1
10' Deli 750 20° 34° 25° 250 26° Forced Evap 4
1
/2" Axial 6 36 min. 1.62 5.49 15.0 1.08 3.48 [.32]
Air Air Sweep 4
1
/2" Axial 3 (4)
Humidity 3
1
/4” Axial 2
12' Deli 750 20° 34° 25° 250 26° Forced Evap 4
1
/2" Axial 6 36 min. 1.62 5.49 15.0 1.08 3.13 [.32]
Air Air Sweep 4
1
/2" Axial 3 (4)
Humidity 3
1
/4” Axial 2
NOTE:A. Case temperature is controlled by a factory installed thermostat and suction solenoid (excluding self contained cases), no other controls are recommended or supported.
B. Data in [ ] Indicates optional Humidity System.
VGD Deli Wedges
TEMPERATURE DISCHG. TYPE DEFROST 115 V. ELECTRICAL CIRCUITS HUMIDITY
MODEL BTU AVG AIR T-STAT/ FAN SIZE FREQ. AIR AIR HUNIDITY
LENGTH REQ’D EVAP PROD DISC VELOC CUT IN NUMBER FAN & E E FANS RECEP- SWEEP SWEEP SYSTEM
APP. FT. TMP TMP TMP @FPM SETTINGS EVAP. COIL OF MOTORS QTY DURATION (STANDARD) LIGHTS TACLE FANS HEATER FANS
30° / 45°Inside All Loads on Parent Case
Outside All Loads on Parent Case
90° Inside Deli 2,670 20° 36° 28° 200-300 28° Forced Evap 4
1
/2" Axial 2 36 min. .36 1.22 15.0 .18 1.04
Inside Meat Total 20° 34° 26° 201-300 26° Air Air Sweep 4
1
/2" Axial 1 (4)
90°Outside Deli 2,670 20° 36° 28° 202-300 28° Forced Evap 4
1
/2" Axial 1 36 min. .18 1.22 15.0 .18 1.04
Outside Meat Total 20° 34° 26° 200-300 26° Air Air Sweep 4
1
/2" Axial 1 (4)
VGM Meat/Fish (Gravity Coil)
4' Deli 360 15° 36° 28° 28° Gravity Air Sweep 4
1
/2" Axial 1 90 min. - 1.77 15.0 36 1.04 [.16]
(1)
6' Deli 360 15° 36° 28° 28° Gravity Air Sweep 4
1
/2" Axial 2 90 min. - 2.93 15.0 72 1.57 [.16]
(1)
8' Deli 360 15° 36° 28° 28° Gravity Air Sweep 4
1
/2" Axial 3 90 min. - 3.54 15.0 1.08 2.09 [.16]
(1)
10' Deli 360 15° 36° 28° 28° Gravity Air Sweep 4
1
/2" Axial 3 90 min. - n/a n/a n/a n/a n/a
(1)
12' Deli 360 15° 36° 28° 28° Gravity Air Sweep 4
1
/2" Axial 3 90 min. - 5.31 15.0 1.08 3.13 [.32]
(1)
NOTE:A. Case temperature is controlled by a factory installed thermostat and suction solenoid (excluding self contained cases), no other controls are recommended or supported.
B. Data in [ ] Indicates optional Humidity System.
SELF CONTAINED DATA
BLOWER COIL GRAVITY COIL
LOW LOW
PRESSURE PRESSURE
SETTINGS H.P. VOLTS AMPACITY SETTINGS H.P. VOLTS AMPACITY
4’ 30# Out 1/3 115 10.9
50# in
6’ 30# Out 1/2 115 19.9
50# in
8’ 30# Out 3/4 208 8.7
50# in /230
10’ 30# Out 1 208 13.0
50# in /230
12’ 30# Out 1 208 13.0
50# in /230