Page 3
SPECIFICATIONS
All specifications are warranted unless noted typical and apply to the 61-340 & 61-342
Stated accuracies are at 23°C±5°C at less than 75% relative humidity and without the battery indicator
displayed.
General specifications
Characteristics Description
Display count 3 3/4 digit liquid crystal display, max count 4000
Numeric update rate 2.5 times / sec
Polarity display Automatic
Over range display “OL” is displayed
Low battery indicator is indicated
Automatic power-off time Automatic power off ≈ 10minutes
Power source
9.0V battery: types- NEDA 1604, JIS006P, IEC6F22
for both 61-340 and 61-342
*Maximum input voltage 1000Vrms CAT III between V and COM
*Maximum floating voltage
1000Vrms CAT III between any terminal and earth ground
Maximum input current 400mA between µA /mA and COM
Overload protection mA connector 500mA (250V) fast blow fuse.
Overload protection 10A connector 10A (250V) fast blow fuse.
V connector V , V , Ω, , , , Hz
µA /mA connector µA, mA, Temp
Temperature Coefficient 0.1×(Spec. Accuracy) per °C, <18°C or >28°C
Battery Life
Alkaline 9V, ≈ 200 hours for 61-340
Alkaline 9V, ≈ 150 hours for 61-342
Form Number 2 TM61340-2 Rev November 2007