John Deere TY25864 Battery Charger User Manual


 
Controls and Operation
OUOD006,0000022 –19–17JUN04–1/1
Control Panel Guide
Mode of Operation Status LEDs Digital Display
Charged Charging Check
Initial power-up, battery not detected O 0.0
No battery or reversed battery detected O 0 (%) or 0.0 (V)
Battery tester activated 0—100
- Battery tester with charged battery O 100
- Battery tester with no battery O 0
Voltage meter activated 0.0—17.0
Alternator tester activated 0—199
- Alternator tester on good alternator O 85—130%
- Alternator tester on bad alternator O 0—199%
2 Amp charge with battery detected O xx (%) or xx.x (V)
15 Amp charge activated O xx (%) or xx.x (V)
40 Amp charge activated O xx (%) or xx.x (V)
Charge complete- Maintain Mode started O 100 (%) or xx.x (V)
100A Engine Start
- Waiting for engine crank O 1.0—16.0
- Cranking engine O 5[rarr ]0
- Cool down after cranking O 120[rarr ]0
Desulfation mode activated X 15 (%) or 16 (V)
Charge aborted X 18.8
O- indicates an LED that is ON continuously.
X- indicates an LED that BLINKS on and off.
10-27
091604