John Deere TY25864 Battery Charger User Manual


 
Controls and Operation
OUOD006,000001A –19–16JUN04–3/3
TYB4763 –UN–07SEP04
TY25864 Control Panel
B—CHARGE RATE Button
CAUTION: NEVER charge a frozen battery.
IMPORTANT: Do not use battery charger to start
vehicle without a battery in it.
7. Set CHARGE RATE button (B) to select 100A START .
NOTE: Only the 100A START, CHARGING, and
BATTERY TYPE LED’s should be illuminated.
IMPORTANT: Do NOT crank engine for more than 5
seconds at a time. Wait for at least 2
minutes between attempts to start
engine.
NOTE: When the engine is not cranking, the battery
charger delivers charge at rate of 20 amps. If
engine is not cranked within 5 minutes, the
charger resets itself to default mode of 2A charge
rate and 12V REGULAR battery type. Proper
battery type and 100A START must be reset in
order to retry engine start.
During engine cranking, the digital display shows
a countdown of available cranking time in
seconds, counting down from 5 to 0.
8. Crank the engine for no more than 5 seconds.
NOTE: After engine cranking, the charger enters a
mandatory 2 minute (120 second) cool down
state. No settings can be changed during this
period. The digital display shows a countdown of
remaining cool down time in seconds, counting
down from 120 to 0, while the 100A START LED
blinks once every second. After the 2 minute cool
down the 100A START LED is illuminated
continuously, indicating that another crank cycle
can be initiated.
9. After the engine starts, unplug the power cord. Then
remove the clamp from the chassis or engine block,
and finally, disconnect the clamp from the battery post.
10. Clean and store the battery charger in a dry location.
10-17
091604
PN=28