Lincoln Electric 355M Welder User Manual


 
TROUBLESHOOTING AND REPAIR
F-78 F-78
POWER WAVE 355M/405M
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
Retest a machine:
If it is rejected under test for any reason that requires you to remove any part which could affect the machine’s
electrical characteristics.
OR
If you repair or replace any electrical components.
INPUT IDLE AMPS AND WATTS
MAXIMUM OUTPUT VOLTAGES
RETEST AFTER REPAIR
Input Volts/Hertz
208/60
230/60
400/60
460/60
575/60
Maximum Idle Amps
4.0
3.3
2.1
2.0
1.8
Maximum Idle KW
0.45
0.45
0.45
0.45
0.45
Input Volts/Hertz
208/60
230/60
400/60
460/60
575/60
50-70 VDC 48.5 - 55 VDC
OCV
115 - 123 VAC
10 Amp Load
111 - 119 VAC
Output Terminals
- No load
X1 - X2 115 Volt Receptacles