Lincoln Electric SVM 119-A Welding System User Manual


 
B-4
OPERATION
B-4
CONTROLS AND SETTINGS
All operator controls are located on the Front
Panel/Nameplate of the machine. See Figure B.1 for
the location of each control.
Figure B.1 - Operator Controls.
1. POWER SWITCH: Toggle switch to turn input
power ON and OFF. Place the lever in the ON
position to turn the WIRE-MATIC 255 ON.
2. PILOT LIGHT: The red LED pilot light located next
to the POWER SWITCH is lit when the power is
ON.
3. VOLTAGE CONTROL POTENTIOMETER KNOB:
Provide continuous adjustment of power source
output voltage over the rated 12 to 28 volt range.
Voltage can be adjusted while welding.
4. WIRE SPEED CONTROL POTENTIOMETER
KNOB: Controls the wire speed from 50 to 600
inches per minute (1.2 to 15.2 m/min). The control
can be preset on the dial to the setting specified on
the Procedure Decal on the inside of the wire com-
partment door. Wire speed is not affected when
changes are made in the voltage control.
NOTE: When the trigger is pulled, the wire feeder
feeds wire at low speed regardless of the wire feed
speed set on the control until the welding arc starts or
2 seconds has elapsed. This feature enhances start-
ing and makes it easier to set the stickout. The 2 sec-
ond limit permits high speed loading of the gun and
cable.
WIRE-MATIC 255
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
ON
OFF
POWER
WIRE-MATIC 255
WARNING
4
3
2
1
1
0
WIRE SPEED
VOLTS
LINCOLN
ELECTRIC