Metrologic Instruments MS9535 Stud Sensor User Manual


 
16
ESTABLISHING BLUETOOTH COMMUNICATION
When the MS9535 Acts as a Client to Other Bluetooth Devices
The MS9535 scanner can also link to other Bluetooth compatible devices such
as a desktop computer, laptop computer, or printer. As a default, the MS9535
will act as the client to another Bluetooth device. The devices’ Bluetooth address
must be scanned to establish a communication link between it and the MS9535
before they will work properly as a complete system. How the communication
link is established depends on the type of Bluetooth address bar code of the
compatible device.
a) If the Bluetooth address is headed with FNC3 and consists of a 12-digit
hex value (e.g.
3
000CA7FFFF99), scan the address bar code to establish
the communication.
³000CA7FFFF99
Example Bluetooth Address with FNC3
b) If the Bluetooth address is NOT headed with FNC3 but is just a common
12-digit hex value (e.g. 000CA7000118), scan the Get Bluetooth Address
code first, and then scan the address bar code.
³ 000CA7FFFFFF
Get Bluetooth Address
000CA7000118
Example Bluetooth Address without FNC3