OM-193 267 Page 22
Turn Output Adjust control to
set arc length to 36.
>Prg 7 035Al 4043 Ar
Adapt ive
4-4. Synergic Controls and Overview
Controls
1 Display
2 Parameter Select Push Button
Press button to move > on display.
The parameter indicated by > is
selected.
3 Increment Push Button
Press increment button to increase
selected parameter.
4 Decrement Push Button
Press decrement button to
decrease selected parameter.
See example at left.
Overview
The built-in synergic control pro-
vides four modes of operation:
Manual Pulse MIG − control func-
tions as a discrete pulsed MIG CC
control.
Mig − control functions as a remote
voltage control.
Stick − unit is placed in CC mode for
SMAW welding.
Synergic Pulser − programs that
use factory-entered values are
used to control process.
Setup screens (see Section 4-6) al-
low programs or modes to be made
inaccessible (locked out) to the op-
erator, and the language used in the
displays (English, French, etc.) to
be defined.
Prg 7 035Al 4043 Ar
>Non Adapt ive
Example
Select top line by pressing
Select push button until > is
on top line. Press Increment
button until Program 7 ap-
pears.
Press Select push button to
select second line, and press
Increment or Decrement but-
ton so Non Adaptive appears.
To select Program 7, set to Non Adaptive, and set Arc Length to 36, proceed as follows:
4
2
3
1
36