Miller Electric Invision 456MP Welder User Manual


 
OM-193 267 Page 24
4-6. Setup Screens
To access Setup screens: turn
welding power source Off, press
and hold Select push button, turn
unit On, and hold push button down
until initial screen leaves.
To exit Setup screens, turn welding
power source Off and then On
again. Parameters that are dis-
played when the Setup screens are
exited are active.
1 Accessible Programs Screen
Select second line of display, and
press Increment or Decrement but-
ton until Accessible Programs is
displayed.
Select third line of display and press
Increment or Decrement button to
access each program and the three
modes as desired. Select the fourth
line and press Increment or Decre-
ment button to define each option
On (accessible) or Off (not accessi-
ble).
Programs and modes that are de-
fined Off are not shown when the
operator scrolls through the dis-
plays in normal operation.
2 Language Screen
Select second line of display, and
press Increment or Decrement but-
ton until Language is displayed. Se-
lect third line of display and press
Increment or Decrement button un-
til desired language is shown. The
choices are English, French, Ital-
ian, Spanish, and German.
2
Set up
Language
>Eng l i sh
1
Set up
Accessible Programs
Manual Pul se Mi g
>Of f