Miller Electric MARK VIII-2 Welder User Manual


 
OM-218 Page 11
SECTION 4 INSTALLATION
ssb9.1 5/94 ST-801 180 / ST-144 567-A
1 Lifting Eye
2 Lifting Forks
Use lifting eye or lifting forks to
move unit.
If using lifting forks, extend forks
beyond opposite side of unit.
3 Rating Label
Use rating label to determine input
power needs.
4 Line Disconnect Device
Locate unit near correct input pow-
er supply.
OR
1
3
Movement
Location And Airflow
18 in
4
(460 mm)
18 in
(460 mm)
Do not block airflow
to bottom of unit.
18 in
(460 mm)
18 in
(460 mm)
18 in
(460 mm)
Special installation may be required
where gasoline or volatile liquids are
present see NEC Article 511 or
CEC Section 20.
2
4-1. Selecting A Location And Moving Polyweld System
Y Disconnect input power conductors
from deenergized supply BEFORE
moving polyweld system.